1. Ishga tushirish ketma-ketligi
Birinchidan, quyi oqim fanini yoqing, so'ngra filtrlash moslamasi uchun quvvat manbaini yoqing. Teskari havo oqimi bilan ishlash qat'iyan man etiladi, chunki bu filtr muhitining shikastlanishiga olib kelishi mumkin. Tizim barqarorlashgandan keyingina (taxminan 3 daqiqa) ifloslantiruvchi manba uskunasini ulash mumkin.
2. Operatsion monitoring
Record differential pressure readings once per hour; when the differential pressure reaches 1.5 times the initial value, preparations should be made to replace the filter media. When processing high-temperature exhaust gases (>60 daraja), filtr muhitining erishi oldini olish uchun sovutish tizimini oldindan faollashtirish kerak. Oziq-ovqat va farmatsevtika sanoati uchun portativ zarrachalar detektori yordamida emissiya kontsentratsiyasining har kuni spot tekshiruvini o'tkazish tavsiya etiladi.
3. O'chirish tartibi
Birinchidan, ifloslantiruvchi manbani o'chiring, so'ngra qolgan chiqindi gazlarni tozalash uchun fanni 10 daqiqa davomida ishlayotgan holda ushlab turing. Qish mavsumida, agar tizim 8 soatdan ko'proq vaqt davomida to'xtatilishi kerak bo'lsa, quvurlar muzlashi va yorilishiga yo'l qo'ymaslik uchun kondensat suvini to'kib tashlang. Uzoq{4}}muddatli saqlash uchun filtr muhitini olib tashlang, ularni mahkam yopib qo'ying va filtrlash moslamasi korpusiga quritgichni joylashtiring.